Skip to content

PowerAction

This AMT method lets you perform an out-of-band power action.

Actions are specified by number. Use the PowerCapabilities method to return the actions availabl for a specific device.

Possible actions are listed in the following table:

Action # Resulting Action
2 Power up/on
4 Sleep
5 Power cycle
7 Hibernate
8 Power down/off
10 Reset
12 Soft power down/off
14 Soft reset
100 Power up to BIOS settings
101 Reset to BIOS settings
104 Reset to secure erase
200 Reset to IDE-R floppy disc
201 Power on to IDE-R floppy disc
202 Reset to IDE-R CD-ROM
203 Power on to IDE-R CD-ROM
400 Reset to PXE
401 Power on to PXE

Example: Request Body

Important Note: More information on obtaining an AMT device's GUID can be found here.

Note: The following code block is an example of what would be the data sent as part of the POST request.

//amt method

{  
   "method":"PowerAction",
   "payload":{  
      "guid":"038d0240-045c-05f4-7706-980700080009", //Replace with an AMT Device's GUID
      "action":2
   }
}

Example : Success ResponseBody

'200':
    {
      "ResponseBody":{
        "returnValue":0,
        "returnValueStr":"SUCCESS"
    }

Return to MPS Methods